Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers. / Yuan, Zishuo; Sticker, Drago; Helms, Hans Christian Cederberg; Kutter, Jörg P.

In: Microfluidics and Nanofluidics, Vol. 26, No. 6, 42, 2022.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Yuan, Z, Sticker, D, Helms, HCC & Kutter, JP 2022, 'Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers', Microfluidics and Nanofluidics, vol. 26, no. 6, 42. https://doi.org/10.1007/s10404-022-02547-x

APA

Yuan, Z., Sticker, D., Helms, H. C. C., & Kutter, J. P. (2022). Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers. Microfluidics and Nanofluidics, 26(6), [42]. https://doi.org/10.1007/s10404-022-02547-x

Vancouver

Yuan Z, Sticker D, Helms HCC, Kutter JP. Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers. Microfluidics and Nanofluidics. 2022;26(6). 42. https://doi.org/10.1007/s10404-022-02547-x

Author

Yuan, Zishuo ; Sticker, Drago ; Helms, Hans Christian Cederberg ; Kutter, Jörg P. / Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers. In: Microfluidics and Nanofluidics. 2022 ; Vol. 26, No. 6.

Bibtex

@article{cc6827fc549c4a8899a83ba28cbcb2dd,
title = "Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers",
abstract = "Proper oxygen supply with controlled gradients, mimicking physiological conditions, is an important feature for getting reliable results from in vitro cell models in medical and pharmaceutical sciences. In this paper, microfluidic chips made from thiol-ene (TE) polymers for the generation of controlled oxygen gradients were employed, and kinetics studies of TE-induced oxygen depletion over time were performed. Dissolved oxygen concentrations inside microchannels under different flow conditions were imaged and measured with a system relying on an oxygen-sensitive dye immobilized in a foil that constituted the bottom of the microchannels. These studies revealed that at least two different processes are involved in the oxygen scavenging process, and that physisorbed water on the channel surfaces and in the immediate bulk is likely playing an important role. The results also showed that flow rate can be used to tune oxygen concentration gradients along a microchannel, with a higher flow rate (2.0 µL/min) generating a shallower gradient while a lower flow rate (0.7 µL/min) generated a steeper gradient. The obtained results provide further insight into the underlying mechanisms behind the scavenging process, but much remains still poorly understood. This includes the long-term behavior of the scavenging properties, which requires flow modulation strategies to stabilize gradients for extended experimental durations. Still, we show how TE polymers provide a practically applicable venue to generate oxygen gradients for cell-based studies in, e.g., microphysiological systems.",
keywords = "Microfluidic devices, Microphysiological systems, Oxygen gradient, Thiol-ene polymer",
author = "Zishuo Yuan and Drago Sticker and Helms, {Hans Christian Cederberg} and Kutter, {J{\"o}rg P.}",
note = "Funding Information: We especially thank PreSens Precision Sensing GmbH for providing the oxygen measurement system including sensor foils, detection unit and software. We also appreciate the financial support from the China Scholarship Council (CSC). We gratefully acknowledge the input provided by Prof. Birger Brodin Larsen (University of Copenhagen) and access to his cell lab facilities. ",
year = "2022",
doi = "10.1007/s10404-022-02547-x",
language = "English",
volume = "26",
journal = "Microfluidics and Nanofluidics",
issn = "1613-4982",
publisher = "Springer",
number = "6",

}

RIS

TY - JOUR

T1 - Generation of transient and tunable oxygen gradients in microfluidic channels utilizing the oxygen scavenging properties of thiol-ene polymers

AU - Yuan, Zishuo

AU - Sticker, Drago

AU - Helms, Hans Christian Cederberg

AU - Kutter, Jörg P.

N1 - Funding Information: We especially thank PreSens Precision Sensing GmbH for providing the oxygen measurement system including sensor foils, detection unit and software. We also appreciate the financial support from the China Scholarship Council (CSC). We gratefully acknowledge the input provided by Prof. Birger Brodin Larsen (University of Copenhagen) and access to his cell lab facilities.

PY - 2022

Y1 - 2022

N2 - Proper oxygen supply with controlled gradients, mimicking physiological conditions, is an important feature for getting reliable results from in vitro cell models in medical and pharmaceutical sciences. In this paper, microfluidic chips made from thiol-ene (TE) polymers for the generation of controlled oxygen gradients were employed, and kinetics studies of TE-induced oxygen depletion over time were performed. Dissolved oxygen concentrations inside microchannels under different flow conditions were imaged and measured with a system relying on an oxygen-sensitive dye immobilized in a foil that constituted the bottom of the microchannels. These studies revealed that at least two different processes are involved in the oxygen scavenging process, and that physisorbed water on the channel surfaces and in the immediate bulk is likely playing an important role. The results also showed that flow rate can be used to tune oxygen concentration gradients along a microchannel, with a higher flow rate (2.0 µL/min) generating a shallower gradient while a lower flow rate (0.7 µL/min) generated a steeper gradient. The obtained results provide further insight into the underlying mechanisms behind the scavenging process, but much remains still poorly understood. This includes the long-term behavior of the scavenging properties, which requires flow modulation strategies to stabilize gradients for extended experimental durations. Still, we show how TE polymers provide a practically applicable venue to generate oxygen gradients for cell-based studies in, e.g., microphysiological systems.

AB - Proper oxygen supply with controlled gradients, mimicking physiological conditions, is an important feature for getting reliable results from in vitro cell models in medical and pharmaceutical sciences. In this paper, microfluidic chips made from thiol-ene (TE) polymers for the generation of controlled oxygen gradients were employed, and kinetics studies of TE-induced oxygen depletion over time were performed. Dissolved oxygen concentrations inside microchannels under different flow conditions were imaged and measured with a system relying on an oxygen-sensitive dye immobilized in a foil that constituted the bottom of the microchannels. These studies revealed that at least two different processes are involved in the oxygen scavenging process, and that physisorbed water on the channel surfaces and in the immediate bulk is likely playing an important role. The results also showed that flow rate can be used to tune oxygen concentration gradients along a microchannel, with a higher flow rate (2.0 µL/min) generating a shallower gradient while a lower flow rate (0.7 µL/min) generated a steeper gradient. The obtained results provide further insight into the underlying mechanisms behind the scavenging process, but much remains still poorly understood. This includes the long-term behavior of the scavenging properties, which requires flow modulation strategies to stabilize gradients for extended experimental durations. Still, we show how TE polymers provide a practically applicable venue to generate oxygen gradients for cell-based studies in, e.g., microphysiological systems.

KW - Microfluidic devices

KW - Microphysiological systems

KW - Oxygen gradient

KW - Thiol-ene polymer

U2 - 10.1007/s10404-022-02547-x

DO - 10.1007/s10404-022-02547-x

M3 - Journal article

AN - SCOPUS:85130096988

VL - 26

JO - Microfluidics and Nanofluidics

JF - Microfluidics and Nanofluidics

SN - 1613-4982

IS - 6

M1 - 42

ER -

ID: 309271820