Standard
Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance. / Ho, Louise; Müller, Ronny; Gordon, Keith C; Kleinebudde, Peter; Pepper, Michael; Rades, Thomas; Shen, Yaochun; Taday, Philip F; Zeitler, J Axel.
In:
Journal of controlled release : official journal of the Controlled Release Society, Vol. 127, No. 1, 2008, p. 79-87.
Research output: Contribution to journal › Journal article › peer-review
Harvard
Ho, L, Müller, R, Gordon, KC, Kleinebudde, P, Pepper, M
, Rades, T, Shen, Y, Taday, PF & Zeitler, JA 2008, '
Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance',
Journal of controlled release : official journal of the Controlled Release Society, vol. 127, no. 1, pp. 79-87.
https://doi.org/10.1016/j.jconrel.2008.01.002
APA
Ho, L., Müller, R., Gordon, K. C., Kleinebudde, P., Pepper, M.
, Rades, T., Shen, Y., Taday, P. F., & Zeitler, J. A. (2008).
Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance.
Journal of controlled release : official journal of the Controlled Release Society,
127(1), 79-87.
https://doi.org/10.1016/j.jconrel.2008.01.002
Vancouver
Ho L, Müller R, Gordon KC, Kleinebudde P, Pepper M
, Rades T et al.
Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance.
Journal of controlled release : official journal of the Controlled Release Society. 2008;127(1):79-87.
https://doi.org/10.1016/j.jconrel.2008.01.002
Author
Ho, Louise ; Müller, Ronny ; Gordon, Keith C ; Kleinebudde, Peter ; Pepper, Michael ; Rades, Thomas ; Shen, Yaochun ; Taday, Philip F ; Zeitler, J Axel. / Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance. In: Journal of controlled release : official journal of the Controlled Release Society. 2008 ; Vol. 127, No. 1. pp. 79-87.
Bibtex
@article{68735704f8a44b5fabd90f16f739c9fc,
title = "Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance",
abstract = "The potential of terahertz pulsed imaging (TPI) to predict the dissolution performance in sustained-release tablets was investigated in this study. Batches of coated tablets with similar weight gain during the coating process at the lab and pilot scales were subjected to non-destructive imaging by TPI and subsequently analysed by dissolution testing. The results from the dissolution tests revealed significant differences in the product performance between the lab and pilot scales (Student t-test, P",
author = "Louise Ho and Ronny M{\"u}ller and Gordon, {Keith C} and Peter Kleinebudde and Michael Pepper and Thomas Rades and Yaochun Shen and Taday, {Philip F} and Zeitler, {J Axel}",
year = "2008",
doi = "10.1016/j.jconrel.2008.01.002",
language = "English",
volume = "127",
pages = "79--87",
journal = "Journal of Controlled Release",
issn = "0168-3659",
publisher = "Elsevier",
number = "1",
}
RIS
TY - JOUR
T1 - Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance
AU - Ho, Louise
AU - Müller, Ronny
AU - Gordon, Keith C
AU - Kleinebudde, Peter
AU - Pepper, Michael
AU - Rades, Thomas
AU - Shen, Yaochun
AU - Taday, Philip F
AU - Zeitler, J Axel
PY - 2008
Y1 - 2008
N2 - The potential of terahertz pulsed imaging (TPI) to predict the dissolution performance in sustained-release tablets was investigated in this study. Batches of coated tablets with similar weight gain during the coating process at the lab and pilot scales were subjected to non-destructive imaging by TPI and subsequently analysed by dissolution testing. The results from the dissolution tests revealed significant differences in the product performance between the lab and pilot scales (Student t-test, P
AB - The potential of terahertz pulsed imaging (TPI) to predict the dissolution performance in sustained-release tablets was investigated in this study. Batches of coated tablets with similar weight gain during the coating process at the lab and pilot scales were subjected to non-destructive imaging by TPI and subsequently analysed by dissolution testing. The results from the dissolution tests revealed significant differences in the product performance between the lab and pilot scales (Student t-test, P
U2 - 10.1016/j.jconrel.2008.01.002
DO - 10.1016/j.jconrel.2008.01.002
M3 - Journal article
C2 - 18291547
VL - 127
SP - 79
EP - 87
JO - Journal of Controlled Release
JF - Journal of Controlled Release
SN - 0168-3659
IS - 1
ER -